AS290 /AS260 Cordless Barcode Scanner User Manual Version: AS290/AS260_UM_EN_V1.2.7 AOPOS
ix Matrix 2 of 5 ...
1 Technical specifications Handheld unit Dimensions Length × Width × Depth: 17.0 × 7.0 × 8.3 cm Weight 201 g Color Gray Battery 1400 mAh Lithium-ion
2 surroundings significantly affect the communication distance in practice. The distance drops quickly in the rainy, high-humidity, or heavy h
3 Cable connector pin-outs descriptions for cradle Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connect
4 Default setting for each barcode Code type Read enable Check digit verification Check digit transmissionMin. codelength Proprietary code ID AIM cod
5 Decode zone High-density series Long-range series
6 Dimensions
7 Parts of the scanner Handheld unit ① Exit window ② Trigger ③ Red LED (Charging indicator) ④ Communication/Charge socket ⑤ Power b
8 Power on, power off handheld unit and charge battery Power on handheld unit: Press the power button (see Parts of the scanner) for two seconds.
9 Installation of cradle Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper conne
i Notice Make sure you carefully read the following information to ensure that your barcode scanner is able to perform at the level for which it is de
10 With RS-232 cable 1. Connect the DB9 serial communication cable with the cradle and the COM port of the computer. 2. Plug the output of the AC/DC
11 Programming instruction The steps of programming are: 1. Scan the SETUP bar code on the parameter setting part. 2. Enter the option mode by scann
12 Description of point coordination and distributed coordination wireless network Notes: 1. In this section, “cluster” denotes an association of a
13 Cluster 1 Cluster 2 2. Sketch map of distributed coordination operating mode This series of cordless barcode scanner is working at 430MH
14 Point coordination wireless communication setting 1. Point coordination wireless communication setting for handheld unit Wireless network topology
15 Low battery indicator: If it is enabled, while the power is low, the power LED on the handheld unit flashes 5 times, and the beeper emits 5 beepers
16 3)Operations to be performed by the base unit / cradle after receiving the command data packet sent from PC. Command packet Operations of base uni
17 SETUPOption barcode Option Alpha. entry Wireless network topology for handheld unit Point coordination Distributed coordination 00* 01 Hand
18 Note: The settings indicated with (※) are valid only when the cradle is in upgrade ready mode. Cradle entering upgrade ready mode Keep pressing t
19 2. Point coordination wireless communication setting for cradle Wireless network topology for cradle: There are two kinds of wireless ne
ii a higher location, generally more than 1 meter above the ground. If working outdoor, the higher location the better.
20 SETUP Option barcode Option Alpha. entry Wireless network topology for cradle※ Point coordination Distributed coordination 00* 01 Cradle RF
21 Distributed coordination wireless communication setting 1. Cluster establishment example 1.1 Establish the wireless link between the cradle and the
22 1.2 Establish the wireless link between successive handheld units and the same cradle. Step 5.0 Please refer to instruction in previous section to
23 2. Distributed coordination wireless communication setting for handheld unit Wireless network topology for handheld unit: There are two kinds of wi
24 SETUP Option barcode Options Value Wireless network topology for handheld unit Point coordination Distributed coordination00* 01 Handheld u
25 3. Distributed coordination wireless communication setting for cradle Wireless network topology for cradle: There are two kinds of wirele
26 Scanning When the scanner is scanning, ensure the scan line crosses every bar and space of the symbol. RIGHT WRONG
27 Keyboard wedge for Cradle Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Ke
28 SETUP Option bar code Option Alpha. entry Keyboard type IBM AT, PS/2 Apple Mac compatibles Reserved 00* 01 02 Keyboard layout USA Turkish
29 SETUP Option bar code Option Alpha. entry END
iii Safety precautions – Danger! Be sure to read the following safety precautions carefully before trying to use the barcode scanner for the first tim
30 RS-232 interface for Cradle Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handsha
31 SETUP Option bar code Option Alpha. entry Flow control None RTS/CTS (Host idle: Low RTS) RTS/CTS (Host idle: High RTS) XON/XOFF ACK/NAK 00
32 USB interface for Cradle USB device type: When the cradle is connected to a PC with a USB cable, it will be identified as a HID keyboard. Keyboar
33 Handheld scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. Th
34 Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction. This function is not effective for all type
35 Visual and audio indication for Handheld unit Power on alert: After power-on the scanner will generate an alert signal to indicate a successful sel
36 UPC-A Read: Format Leading zero Data digits (11 digits) Check digitCheck digit verification: The check digit is optional. Check digit trans.: By
37 UPC-E Read: Format Leading zero Data digits (6 digits) Check digitsCheck digit verification: The check digit is optional and made as the sum of th
38 EAN-13 Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical
39 EAN-8 Read: Format Data digits (7 digits) Check digitCheck digit verification: The check digit is optional and made as the sum of the numerical va
iv Safety precautions – Warning! Warning! This symbol indicates information that, if ignored or applied incorrectly, can create the possibility of d
40 Code 39 Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆Check digit verification: The check digit is optional and made as the sum m
41 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00* 01 Check digit transmissi
42 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module
43 Industrial 2 of 5 Read: Format Data digits (variable) Check digit (optional) Max./Min. code length: Refer to Max./Min. code length of Code 39. Cod
44 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of
45 Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum module
46 Code 128 Read: Format Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum module 103 of all
47 Code 93 Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The check digit is made as the sum module 47 of the
48 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)Check digit verification: The check digit is present
49 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey h
v Cradle with RS-232 cable and adaptor z Power the cradle only with a power outlet whose voltage matches that marked on the adaptor s
50 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The UK/Plessey has one or two optional check di
51 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of
52 China Post Read: Format 11 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group sele
53 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, exce
54 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion g
55 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer t
56 PDF417 This decoder is only applied with a specified firmware. The symbol size in the standard of PDF417 says, number of rows: 3 to 90, and number
57 MicroPDF417 This decoder is only applied with a specified firmware. Read: Format Data characters (variable) Max. /Min. code length: Refer to Max./M
58 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the sym
59 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Max. code length 00-99 00-99 10* Min. code length 00-99 00-99 10*
vi Safety precautions – Caution! Caution! This symbol indicates information that, if ignored or applied incorrectly, can create the possibility of p
60 G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID
61 FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substitu
62 SETUP Option bar code Option Alpha. entry Prefix string setting 0-22 characters None 00-FF16 00* Suffix string setting 0-22 characters <EN
63 G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code I
64 String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission
65 SETUP Option bar code Option Alpha. entry Prefix transmission Disable Enable 00* 01 Suffix transmission Disable Enable 00 01* Code name transm
66 Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disabl
67 Test Chart (Continued) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) GS
68 Troubleshooting Problem Possible causes Possible solutions No power to the scanner. Check the system power. Ensure the power supply is connected.
69 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not allo
vii insulation of the power cord and create the danger of fire and electrical shock. z Never pull on the power cord when unplugging it. Doing so can d
70 ASCII table for keyboard wedge for RS-232 H L 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right
71 Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method
72 Return default parameters All parameters of handheld unit return to default setting WARNING: If you wish to return all parameters of the handheld
73 Display firmware version & radio communication setting Cradle firmware version display If you wish to display the firmware version of the cra
74 Quick setting to point or distributed coordination wireless network The steps of setting are: 1. Both the handheld unit and the cradle are in norm
75 Configuration alphanumeric entry barcode
viii Contents Notice................................